With control spool types E, E1, EA, W, W1, WA; in longitudinal control spool direction, there is sufficient positive overlap without shock/vibration load; observe the installation orientation with regard to the main direction of acceleration.
hydraulic
Size
6
10
Maximum operating pressure
bar
315
Maximum operating pressure
Port P
bar
315
Port T
bar
210
Port A
bar
315
Port B
bar
315
Maximum flow
l/min
80
180
Nominal flow
l/min
4
8
16
32
25
50
75
Hydraulic fluid
see table below
Hydraulic fluid temperature range
°C
-20 … +80
preferably
°C
+40 … +50
Viscosity range
mm²/s
20 … 380
preferably
mm²/s
30 … 46
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)
Class 20/18/15 according to ISO 4406 (c)
Hysteresis
%
≤ 0.1
Range of inversion
%
≤ 0.05
Response sensitivity
%
≤ 0.05
Zero shift upon change of
Hydraulic fluid temperature
%/10 K
≤ 0.15
Operating pressure
%/100 bar
≤ 0.1
1)
The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
For more information and data on the use of other hydraulic fluids please contact us.
There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).
The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.
Flame-resistant - containing water:
Maximum pressure differential per control edge 175 bar
Pressure pre-loading at the tank port > 20 % of the pressure differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP 50 % to 100 %
electrical
Size
6
10
Voltage type
Direct voltage
Maximum current consumption
of the amplifier
A
2
of the amplifier (impulse current)
A
3
Solenoid coil resistance
Cold value at 20 °C
Ω
2.65
4.55
Maximum hot value
Ω
4.05
6.82
Actuated time
%
100
Maximum coil temperature 1)
°C
150
Protection class according to DIN EN 60529
IP65 (with mating connector mounted and locked)
Power supply
V
24
Supply voltage range
V
19,4 … 35
Earthing (GND)
V
0
Command value input
"A1"
V
± 10
Command value input range
"F1"
mA
4 … 20
Actual value output
"A1"
V
± 10
Actual value output range
"F1"
mA
4 … 20
1)
Due to the surface temperatures occurring at solenoid coils, the European standards ISO 13732-1 and ISO 4413 need to be adhered to.